Customer Service 1.888.878.2497 M-F 8am-5pm EST info@healthgoods.com  

Site Search


Free HealthE Newsletter

type email address

Fitness
Indoor Air Quality
  hepa room air cleaners
  hepa vacuum cleaning systems
  vapor steam cleaning systems
  germ-free humidifiers
  indoor air quality testing
  allergen testing
  radon testing
Water Quality
Allergen Control
Personal Care
Bed & Bath
Appliances
Gardening
Home Test Kits
Conservation
Household
Wellness
Clearance
 

Health
Fitness
Nutrition
Healthy Home
Environment
Energy
 

Philosophy
Contact
Ordering
Shipping
Guarantee
Policies
Security
Privacy
FAQ's
Feedback
Free Newsletter
Site Map
 

Click to View Better Business Bureau Reliability Report

 

 

Verisign Payment Services

 

Coop America Green Business

 

Water Quality Association Member

 

Organic Trade Association Member

 
 

Path: Home>Shopping Center>Indoor Air Quality Products>HEPA Room Air Cleaners>Room Air Cleaner Capcaities and Sizing

Room Air Cleaner Capacities and Sizing

Determine the size of your room by measuring how wide and how long it is. Multiply the width x length and this is the total square feet of the room space. To find the volume of the room, multiply the floor space by the room height. To compare room volume to air cleaner capacities, determine the number of air changes per hour (ACH) you desire. Indoor air quality professionals and Allergists recommend at least 2 room air changes per hour, designated as 2 ACH. Spaces with high pollutants may require higher air changes to reduce pollutant levels.

To determine how much air must be moved through the air cleaner to provide 2 ACH, you take the total volume of the room and multiply by 2. Air cleaners provide air flow performance in cubic feet per minute, so you must take your total volume of air for 2 ACH and divide by 60 minutes to get a value for cubic feet per minute (CFM).

Note: The location of an air cleaner in a room can effect performance. Try to place the unit in a central location that allows the greatest degree of unobstructed air flow around the air cleaner.

Air Cleaner Room Sizing

Air Cleaner Sizing Example

Room Size
12' x 20' = 240 square feet of floor space (sq. ft.).
Ceiling Height is 8'
240 sq.ft. x 8' = 1920 cubic feet of air volume (cu. ft.).
Two Room Air Changes per Hour
1920 cu. ft. x 2 = 3840 cu. ft. per hour (60 minutes).
Volume per Minute
3840 ÷ 60 = 64 cubic feet per minute (cfm).

In the previous example, an air cleaner must provide a system flow rate of 64 cubic feet per minute of filtered air to clean all the air in a room two times per hour.

Note: Some air cleaner manufacturers provide air flow performance ratings when the fan and motor are under no load or not in the system. Air cleaner system air flow rates can diminish up to 60% of the no load air volume when the filter media is installed due to the resistance to the air flow through the filter media. Please consider this air flow rate reduction when sizing air cleaners with untested system air flow rates.

Room Size and Flow Rate Requirement Chart
(based on 8' ceiling height)
Room Size Air Cleaner Flow Rate to Achieve 2 ACH* Air Cleaner Flow Rate to Achieve 3 ACH* Air Cleaner Flow Rate to Achieve 4 ACH*
75 sq. ft. 20 cfm 30 cfm 40 cfm
100 sq. ft. 27 cfm 40 cfm 53 cfm
125 sq. ft. 33 cfm 50 cfm 67 cfm
150 sq. ft. 40 cfm 60 cfm 80 cfm
175 sq. ft. 47 cfm 70 cfm 93 cfm
200 sq. ft. 53 cfm 80 cfm 107 cfm
225 sq. ft. 60 cfm 90 cfm 120 cfm
250 sq. ft. 67 cfm 100 cfm 133 cfm
275 sq. ft. 73 cfm 110 cfm 147 cfm
300 sq. ft. 80 cfm 120 cfm 160 cfm
325 sq. ft. 87 cfm 130 cfm 173 cfm
350 sq. ft. 93 cfm 140 cfm 187 cfm
375 sq. ft. 100 cfm 150 cfm 200 cfm
400 sq. ft. 107 cfm 160 cfm 213 cfm
425 sq. ft. 113 cfm 170 cfm 227 cfm
450 sq. ft. 120 cfm 180 cfm 240 cfm
475 sq. ft. 127 cfm 190 cfm 253 cfm
500 sq. ft. 133 cfm 200 cfm 267 cfm
525 sq. ft. 140 cfm 210 cfm 280 cfm
550 sq. ft. 147 cfm 220 cfm 293 cfm
575 sq. ft. 153 cfm 230 cfm  
600 sq. ft. 160 cfm 240 cfm  
625 sq. ft. 167 cfm 250 cfm  
650 sq. ft. 173 cfm 260 cfm  
675 sq. ft. 180 cfm 270 cfm  
700 sq. ft. 187 cfm 280 cfm  
725 sq. ft. 193 cfm 290 cfm  
750 sq. ft. 200 cfm 300 cfm  
775 sq. ft. 207 cfm    
800 sq. ft. 213 cfm    
825 sq. ft. 220 cfm    
850 sq. ft. 227 cfm    
875 sq. ft. 233 cfm    
900 sq. ft. 240 cfm    
925 sq. ft. 247 cfm    
950 sq. ft. 253 cfm    
975 sq. ft. 260 cfm    
1000 sq. ft. 267 cfm    
1025 sq. ft. 273 cfm    
1050 sq. ft. 280 cfm    
1075 sq. ft. 287 cfm    
1100 sq. ft. 293 cfm    
1125 sq. ft. 300 cfm    

*ACH = Air Changes per Hour. A term to represent how many times all the air in a room could pass through an air cleaner in an hour.

Click Here to go to the main HEPA Room Air Cleaner System shopping page

 

 

Health
Environmental Diseases from A-Z

Healthy Home
Household Hazardous Products

Environment
Toxic Air Pollutants

Nutrition
Keeping Cholesterol Under Control

Fitness
Can Physical Activity Reduce My Chances of Getting a Heart Attack?

Energy
Ethical Dimensions of Our Energy and Environmental Crises
 

home | shopping | education | company | site map | contact

 

Copyright © 1998-2007 by HealthGoods, LLC. All Rights Reserved.
The use of this site is subject to our Copyright, Conditions of Use, and Disclaimer.