Large Digital LED Display -
Provides the numerical value of the relative humidity in a room.
Accurate to 5%.
On/Off Switch - Press the
switch to turn the unit on/off.
Auto/Sleep Mode - Activate
the Auto or Sleep mode by pressing the button. Automatic Mode provides the
ideal air humidity relative to the room temperature
by regulating the output based on the selected
humidity level.
Sleep Mode sets the humidity
level to 60% and the operating time to 6 hours and
turns on the pre-heating function. The output
quantity is also regulated based on the difference
between the actual and selected humidity values.
Hygrostat Humidity Control -
Press the button several times to select the humidity level. The
selected level is displayed numerically. As soon as the room
humidity exceeds the selected setting, the unit shuts off
automatically. Also provides an option for continuous
humidification.
Pre-Heating Option - Pressing
the pre-heat control button will heat the water to 176°F before
it reaches the nebulizer chamber. The pre-heat indicator light
will illuminate.
Mist Output Control - Mist
output is controlled by pressing the button several times for
low/medium/high. The output setting is shown as a circular bar
scale next to the numerical humidity level.
Timer Control - Press the
button to set the humidifier to operate from 1 to 8 hours or on
continuous operation.
Cleaning Indicator - This
symbol comes on every 2 weeks, depending on the level of use. It
is a reminder to check the unit for deposit build-up and does
not actually monitor the unit's cleanliness. Indicator display
light can be cancelled.
Empty Indicator - As soon as
the water level sensor indicates the water reservoir is empty,
the unit shuts off the ultrasonic vibrator disc and an empty
indicator light turns on.